- Home
- »
- Our Products
- »
- Aluminium Conductors
Aluminium Conductors
Silicone Conductor Covers
Minimum Order Quantity: 1000 Kg
Product Brochure
| Diameter | 25 mm |
| Usage/Application | Industrial |
| Shape | Rectangular |
| Color | Red |
| Brand | Power Cable Corporation |
| Material | Silicone |
Insulcover is a Wrap Around Line Cover that provides retrofit insulation for Overhead Conductors to help prevent electrical outages caused by trees or wildlife coming into the contact with distribution lines. It is manufactured from high quality Non-tracking Cross-linked Polyolefin material. Gala Overhead Line Covers can be used in many applications to enhance the insulation up to 400 kV. Insulcover is designed to insulate existing bare lines without costly conductor replacement expenditure or additional line hardware.
Installation is easy by using the Split Insulation Tube Tool which remains stationery at single location.
- High Di-electric strength
- Excellent UV stabilized & weather resistant
- Passed 5000 Hrs. UV test
- Tracking & Erosion resistant
- Prevent Conductor from Chemical corrosion effected by strong acid, alkali, salt etc.
- Halogen free, Flame retardant
- Insulcover is available in five sizes that covers conductors up to 800 sq. mm.
| Selection Chart | |||
|---|---|---|---|
| Gala Code | Conductor size (sq.mm.) | Conductor size in Dia. (mm) | Packaging (Mtr./Roll) |
| GOC 1 | ≤ 99 | upto 10 | 30 |
| GOC 1A | upto 185 | upto 15 | 30 |
| GOC 2 | upto 300 | upto 22 | 30 |
| GOC 3 | upto 400 | upto 28 | 30 |
| GOC 4 | upto 800 | upto 38 | 30 |
| Technical Specification | ||
|---|---|---|
| PROPERTIES | VALUE | TEST METHOD |
| Tensile Strength | 9 N/mm2 (Mpa) (min.) | ASTM D638 |
| Ultimate Elongation | 250% (min.) | ASTM D638 |
| Density | 1.20 ± 0.2gm/cm3 | ASTM D792 |
| Hardness | 40 ± 5 Shore D | ASTM D2240 |
| Water Absorption | 0.5% (max.) | ASTM D570 |
| Heat Shock (90°C for 4 hrs.) | No Cracking | ASTM D2671 |
| Flame Retardant | Pass | ASTM D2671 |
| Low Temperature Flexibility (-40°C for 4 hrs.) |
No Cracking | ASTM D2671 |
| Continuous Temperature Limit | -45°C to +105°C | IEC 216 |
| Dielectric Strength | 20kV/mm. (min.) | ASTM D149 |
| Volume Resistivity | 1 x 1013 Ohm.cm (min.) | ASTM D257 |
| Dielectric Constant | 5 (max.) | ASTM D150 |
| UV Resistance (5000 Hrs.) | No Colour Change | ASTM DG154 |
| Resistance to Tracking & Erosion | No Tracking, Erosion or Flame failure up to 3.25 kV for 20 min | ASTM D2303 |
* The above mentioned values are typical analytical values obtained on material When tested as per applicable standards under controlled laboratory conditions and should not be construed as specfications of the product.
Additional Information:
- Item Code: GOC
- Production Capacity: 200000
- Delivery Time: READY
- Packaging Details: WOODEN SPOOL
Conductor Covers For Overhead Lines
Product Brochure
| Diameter | 10 mm |
| Usage/Application | Overhead |
| Shape | Round |
| Color | BROWN |
| Country of Origin | Made in India |
Gala Silicone Interlocking Overhead Line Covers are made from high quality non-tracking silicone rubber that are designed for field installation over bare conductors. These covers provide a layer of electrical insulation for Phase-to-Phase and Phase-to-Ground protection from bird and animals. The GSIOC provides electrical insulation, UV resistance and tracking resistance. Provide Insulation upto 33 kV.
General Product Properties:- High Di-electric strength
- Tracking & Erosion resistant
- Excellent UV stabilized & weather resistant
- Operating temperature ranges from -70°C to +180°C
- Prevent Conductor from Chemical corrosion effected by strong acid, alkali, salt etc.
- Halogen free
- Easy to install
| Technical Specification* | ||
|---|---|---|
| PROPERTIES | TEST METHOD | TYPICAL VALUE |
| Physical: | ||
| Tensile Strength | ASTM-D-638 | 4 N/mm 2 (Min.) |
| Elongation | ASTM-D-638 | 200% (Min.) |
| Density | ASTM D792 | 1.10 - 1.45 gm/cm 3 |
| Hardness | ASTM D2240 | 65 ±5 Shore A |
| Low Temp. Flexibility | ASTM D2671 | No Cracking of material at -20 Deg. C for 4 Hr |
| Water Absorption (after 24 Hrs. at 23 Deg. C) | ASTM D570 | 0.5% (max) |
| Thermal: | ||
| Thermal Ageing | ASTM-D-2671 | 150 0C for 168 hrs. |
| Tensile Strength | ASTM-D-638 | 3.0 N/mm 2 (Min.) |
| Elongation | ASTM-D-638 | 100% (Min.) |
| Electrical: | ||
| Di-electric Strength | ASTM-D-149 | 10 kV / mm (min) |
| Volume Resistance | ASTM-D-257 | 1x10 10 Ohm cm (Min) |
| Tracking and Erosion Resistance | ASTM-D-2303 | No tracking or erosion to top surface or flame failure after 1 hr. at 2.5 kV 1 hr. at 2.75 kV 1 hr. at 2.5 kV 1 hr. at 3.0 kV 20 min. at 3.25 kV |
* The above mentioned values are typical analytical values obtained on material when tested as per applicable standards under controlled laboratory conditions and should not be construed as specifications for the product
| Selection Chart | ||||
|---|---|---|---|---|
| Gala Code | Conductor Size Sq. mm. | Conductor Size in Dia. (mm) | Thickness (mm) | Packaging (Mtr./Roll) |
| GSIOC-15 | upto 185 | upto 15 | 2.00 | 15 |
| GSIOC-20 | upto 300 | upto 20 | 2.00 | 15 |